Radon mitigation systems: how much they lower levels, and what they cost

A radon mitigation system pulls soil gas from under a house and vents it outside before it can collect indoors. Pennsylvania records a test before and after many installations, which makes it possible to see what 26,781 systems achieved.

9.0 → 1.1median pCi/L before and after
95%tested below 4.0 pCi/L after
73%tested below 2.0 pCi/L after

Source: Pennsylvania Department of Environmental Protection mitigation records, 2020–2026; among systems with a reported post-mitigation test (26,781 systems). Not a random sample. Method.

How a typical system works

The most common design, recorded as sub-slab ventilation, is a plastic pipe set into a hole in the basement floor or slab, with a small fan that runs all the time. The fan lowers the air pressure under the floor so that soil gas flows into the pipe instead of into the house, and the pipe releases it outdoors. Installers also seal cracks and other openings in the foundation; the EPA notes that this makes such a system more effective and cost-efficient (EPA, A Citizen's Guide to Radon, page 9).

Homes with a crawl space usually get a sealed plastic sheet over the soil with the suction under it (sub-membrane depressurization). Slab-on-grade homes get suction through the slab. Some newer homes have a passive pipe built in, which a fan can activate later.

Results by starting level

The higher the starting level, the more a system has to remove. In the Pennsylvania records, results after the work were similar across starting levels, with a lower share under 4.0 pCi/L only among systems whose first test was very high:

Level after mitigation by level before, Pennsylvania residential systems
Level before (pCi/L)Median afterBelow 4.0 after
under 4848 systems1.095%
4 to 9.913,307 systems1.196%
10 to 19.97,456 systems1.194%
20 and above5,170 systems1.290%

Dot colour shows the EPA range the median after mitigation falls in: under 2, 2 to 3.9 (EPA: consider fixing), 4 and above (EPA: fix). It describes the median test after mitigation, not any home.

Source: Pennsylvania Department of Environmental Protection mitigation records, 2020–2026; among systems with a reported post-mitigation test (26,781 systems). Not a random sample. Method.

These are systems for which a test after the work was reported. Homes without a reported post-test are not in this table, and the records do not say why a test is missing, so the share of systems that work could be higher or lower than shown. The EPA says it is a good idea to retest a home every two years to be sure radon levels remain low (EPA, A Citizen's Guide to Radon, page 10).

Area results cannot tell you your home's level. The EPA recommends testing all homes below the third floor.

What each type of system costs

Price by system type, residential, 2020–2026
System type (as recorded)Median price
Sub-Slab Ventilation - Generic50,365 systems$1,250
Activate A Passive System5,036 systems$735
Sub-Slab Pit Cut-Out1,280 systems$1,075
Modify An Existing System923 systems$550
Passive Depressurization433 systems$685
Slab-On-Grade Depressurization401 systems$1,250
Sub-Membrane Depressurization399 systems$2,145
Sealing394 systems$1,195
Sub-Slab Combo387 systems$1,450
Ventilation Combo221 systems$1,475
Depressurize Captive Membrane158 systems$2,100
Air Exchange147 systems$2,000

Source: Pennsylvania, 60,311 mitigation systems, 2020–2026, nominal dollars, as reported by installers to the Pennsylvania Department of Environmental Protection (data retrieved from data.pa.gov, updated 2026-10-13). Method.

Prices by year and by county are on the radon mitigation cost page.

Professional or do-it-yourself

Pennsylvania requires certification for radon testing and mitigation (PA DEP, radon certification). The records on this site are reports made to DEP; they say nothing about fan and pipe kits installed by owners themselves. Whoever installs a system, retesting afterwards is how to find out whether the level dropped.

Buying a house that already has a system

A visible pipe with a fan, or a small gauge on the pipe (a U-tube manometer), means a system was installed. It does not show the current level. Asking for the most recent test, and testing again, is how a buyer finds out whether the system is working.