Radon levels chart: what your test result means
Radon is measured in picocuries per liter of air (pCi/L). This chart puts a test result next to the levels the US Environmental Protection Agency (EPA) uses, and next to 1,804,822 real test results reported in Pennsylvania.
- Under 2: average outdoor air ~0.4, average US home ~1.3 (the two markers above the bar)
- 2 to 3.9: EPA says consider fixing
- 4 and above: EPA recommends fixing
Radon levels and what the EPA says to do
Average US home: about 1.3. Average outdoor air: about 0.4.
EPA: consider fixing your home.
EPA action level: fix your home.
EPA guidance quoted from What is EPA's Action Level for Radon and What Does it Mean? and A Citizen's Guide to Radon, page 7. Bq/m³ converted at 1 pCi/L = 37 Bq/m³ and rounded.
The EPA also says that no level of radon is known to be safe, which is why it suggests considering a fix between 2 and 4 pCi/L. The World Health Organization recommends that countries set a reference level of 100 Bq/m³ (about 2.7 pCi/L), and no higher than 300 Bq/m³ (WHO, Radon and health). In the United States, testing and fixing decisions follow the EPA levels.
How common is each level? 1,804,822 Pennsylvania basement tests
Pennsylvania publishes the radon tests reported to its Department of Environmental Protection. These are 1,804,822 tests taken in the basements of homes between 1986 and 2026.
| Result (pCi/L) | Tests | Share |
|---|---|---|
| 0 to 0.9 | 226,351 | |
| 1 to 1.9 | 412,298 | |
| 2 to 2.9 | 305,053 | |
| 3 to 3.9 | 209,693 | |
| 4 to 4.9 | 123,558 | |
| 5 to 9.9 | 285,828 | |
| 10 to 19.9 | 142,996 | |
| 20 and above | 99,045 |
Source: Pennsylvania Department of Environmental Protection, radon test results reported to DEP, 1986–2026; data retrieved from data.pa.gov, updated 2026-10-20. Residential basement tests; tests, not homes; not a random sample. Method.
Area results cannot tell you your home's level. The EPA recommends testing all homes below the third floor.
These shares describe Pennsylvania tests only. They show how widely results spread, not what to expect in any one house; two neighbouring homes can test far apart.
Basement, first floor or slab: where the test was taken matters
Radon comes from the ground, so the lowest lived-in level usually reads highest. In the same Pennsylvania records:
| Floor tested | Tests | Median (pCi/L) | At or above 4.0 |
|---|---|---|---|
| Basement | 1,804,822 | 2.8 | 36% |
| First Floor | 254,129 | 1.5 | 18% |
| Slab On Grade | 96,974 | 2.0 | 25% |
| Second Floor | 38,683 | 1.1 | 13% |
| Crawl Space | 22,667 | 1.4 | 12% |
Source: Pennsylvania Department of Environmental Protection, radon test results reported to DEP, 1986–2026; data retrieved from data.pa.gov, updated 2026-10-20. Residential tests, by floor tested; tests, not homes; not a random sample. Method.
Look up a Pennsylvania ZIP code
1,632 Pennsylvania ZIP codes have at least 10 residential basement tests on record; others are not shown. Levels: Pennsylvania DEP radon test results, 1986–2026; tests, not homes.
Prices in the lookup: Pennsylvania DEP mitigation records, 2020–2026, nominal dollars, shown only for ZIP codes with at least 10 systems and marked "few systems" under 30. Method.
Area results cannot tell you your home's level. The EPA recommends testing all homes below the third floor.
Is my number high? Results people ask about
For each result below: where it sits on the EPA scale, how many Pennsylvania basement tests came in higher, and what happened in mitigation systems whose first test was near that level.
| Result (pCi/L) | Bq/m³ | EPA range | PA tests higher | Systems that started near it (2015–2026) | Their median after | Systems priced (2020–2026) | Median price |
|---|---|---|---|---|---|---|---|
| 2.7 | 100 | consider fixing | 51% | 117 | 1.0 | 166 | $1,250 |
| 2.9 | 107 | consider fixing | 48% | 207 | 1.0 | 282 | $1,225 |
| 3.5 | 130 | consider fixing | 40% | 359 | 1.0 | 394 | $1,250 |
| 4.0 | 148 | fix | 35% | 2,904 | 1.0 | 2,930 | $1,231 |
Source: Pennsylvania Department of Environmental Protection, radon test results reported to DEP, 1986–2026; data retrieved from data.pa.gov, updated 2026-10-20. Residential basement tests; tests, not homes; not a random sample. Method.
Source: Pennsylvania Department of Environmental Protection mitigation records, 2015–2026; among systems with a reported post-mitigation test. The ±0.25 pCi/L ranges overlap, so a system can be counted in two rows. Not a random sample. Method.
Prices: Pennsylvania mitigation systems 2020–2026 with a first test in the same range, nominal dollars, as reported by installers to the Pennsylvania Department of Environmental Protection. Method.
Area results cannot tell you your home's level. The EPA recommends testing all homes below the third floor.
"Started near it" means a first test within 0.25 pCi/L of the result. A 2.7 is close to the middle of Pennsylvania results: about half of basement tests come in higher. For a short-term result of 4.0 or more, the EPA recommends a follow-up test (a long-term test or a second short-term test) before deciding to fix the home. Below 4.0, the EPA says you may want to test again sometime in the future (EPA, A Citizen's Guide to Radon).
What fixing it costs
Across 9,516 residential systems reported in Pennsylvania for 2025, the median price reported to the state was $1,395; half cost between $1,181 and $1,550.
Source: Pennsylvania, 9,516 mitigation systems, 2025, nominal dollars, as reported by installers to the Pennsylvania Department of Environmental Protection (data retrieved from data.pa.gov, updated 2026-10-13). Method.
See radon mitigation cost for prices by year, system type and county, and radon mitigation systems for how much they lower levels.